LevelOne Switch IPS 0008 User Manual

IPS-0008  
IP Power Switch  
User Manual  
Ver 1.0.1-0710  
1
 
Safety instructions  
Follow these safety instructions to avoid injury to self and damage to the  
IPS-0008.  
ƒ
To reduce the risk of fire or electric shock, install the unit in a  
temperature-controlled indoor area free of conductive  
contaminants. Do not place the unit near liquids or in an  
excessively humid environment.  
ƒ
ƒ
Do not allow liquids or foreign objects to enter the unit.  
The unit does not contain any user-serviceable parts. Do not open  
the unit.  
ƒ
ƒ
Servicing, maintenance, and repair for this equipment must be per-  
formed by qualified service personnel. Remove rings, watches and  
other jewelry before servicing the unit.  
Before maintenance, repair or shipment, the unit must be  
completely switched off and unplugged and all connections must  
be removed.  
ƒ
ƒ
ƒ
Before plugging in the power cord of the device, make sure that the  
power source rating matches the power rating of the IPS-0008.  
Use a standard power cord when you connect any device to the  
outlets of IPS-0008.  
This unit has been provided with a real time clock circuit. There is a  
danger of explosion if the battery is incorrectly replaced. Replace  
only with a 3V Lithium cell (CR2032) or equivalent type. Discard  
used batteries according to the manufacturer’s instructions.  
3
 
Table Content  
4
 
1. Introduction  
Congratulations on purchasing the IPS-0008, an intelligent power  
management system. The IPS-0008 provides the useful ability of  
managing power for any combination of network equipment connected  
to it. You can control the power on/off for any device connected to the  
IPS-0008, manually or remotely, using a console or Ethernet connection.  
The IPS-0008 comes with eight power outlets, each of which can be  
monitored and controlled through the console or web interfaces. You can  
also use the front panel to operate the power outlets. The IPS-0008 is  
also equipped with a console port for connecting an EMD  
(Environmental Monitored Device, optional) for sensing temperature and  
humidity along with two alarms that can be activated when either of the  
sensors shows unusual values. The IPS-0008 is provided with two digital  
outputs which you can use for connecting status indicators or digital  
switches.  
The device is designed to remember the configuration of each outlet and  
inlet and is also able to measure the input and output current  
consumption.  
1
 
 
1.1. Features  
ƒ
Eight power outlets that can be turned on or off in multiple ways,  
with easy monitoring of current consumption  
Active extended devices via digital outputs  
Monitor and manage connected devices and sensors remotely  
Control the IPS-0008 manually, or remotely through console or  
network  
ƒ
ƒ
ƒ
ƒ
ƒ
Intelligent turn on/off devices based on event occurrence or  
planned schedule  
Comprehensive power management and flexible configuration  
through web browser, NMS, Telnet, SNMP, or HyperTerminal  
(console)  
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Configurable user security control  
User-friendly interface to display input and output status  
Detailed data-logging for statistical analysis and diagnostics  
Upgrade utility for easy firmware upgrade  
Event notification through SNMP trap or Email alerts  
Daily history report through Email  
Supports SSL V3 and SSH V1 protocol  
Administrator and multiple users with password protection for  
double-layer security  
ƒ
ƒ
ƒ
Address-specific IP security masks to prevent unauthorized access  
Available in 110V and 220V models  
Optional versatile sensors supported through EMD (Environmental  
Monitoring Device) inputs  
2
 
 
1.2. Package contents  
Make sure that your package has the following items. If any of items is  
missing or damaged, contact your nearest service center or vendor.  
1. IPS-0008 IP Power Switch  
2. Rack-mount Brackets  
3. U-type Handle  
4. U-type Handle Screws  
5. Bracket Screws  
6. Feet Screws  
7. CD Manual  
8. Rubber Feet  
9. Quick Installation Guide  
10. Power Cord  
11. Console Cable  
3
 
 
1.3. Hardware Components  
Take a moment to familiarize you with the IPS-0008 front and rear panels.  
The following sections provide descriptions about the front and rear  
panel components and how to use them.  
1.3.1. Front Panel  
Component  
Description  
1
Output power status  
indicator (A ~ H)  
Displays output current, power  
status, and remote control status for  
each power outlet A through H.  
2
3
4
Input power  
Displays percentage of input power  
consumed.  
consumption indicator  
Status indicator  
Displays input current, voltage,  
frequency, and error code.  
Remote control button  
Enables you to manually control  
power and enable remote control  
configuration for each power outlet  
A through H.  
4
 
 
Component  
Description  
5
6
Reset button  
Enables you to reset the IPS-0008  
in case the system locks up.  
Operation mode DIP  
switch  
Sets the mode of operation for the  
IPS-0008. S1 off, S2 off: Normal  
operation (default mode)  
7
8
Serial (CONSOLE) port Enables you to configure the  
IPS-0008 using the serial port. You  
can also connect an optional EMD  
to this port.  
Ethernet (LAN) port  
Enables you to configure the  
IPS-0008 through a LAN or WAN.  
5
 
1.3.2. Status Indicator  
The front panel of the IPS-0008 has several LED indicators that provide  
information about the input and output power status. The following table  
describes these status indicators.  
Description  
Status Indicator  
Displays status of each power  
outlet (A ~ H)  
Output power status indicator (A ~  
H)  
as follows:  
1. Current level indicator:  
Displays the amount of current  
being drawn by the connected  
output device through the  
power outlet.  
2. Outlet power indicator:  
Displays the out- let power  
status.  
Grey: power off  
Green: power on  
3. Remote control indicator:  
Displays the remote control  
status of each outlet.  
Grey: remote control is  
enabled.  
Red: remote control is  
disabled.  
4. Control button:  
Allows manual control of each  
power outlet. Press repeatedly  
to switch between remote  
control and power on/off  
mode. See “Using the control  
but- tons” on page 7  
6
 
 
Description  
Status Indicator  
Input power consumption  
indicator  
Displays input power consumed  
by the output devices connected  
to the IPS-0008 outlets. The  
power consumption is displayed  
as a percentage value.  
Displays input voltage (Volts),  
input current (Ampere), and  
frequency (Hz), sequentially on  
the 7-segment switching display.  
This indicator also shows system  
errors in the form of an error code  
such E01, E02, E03, and so on.  
Refer to “Error codes” on page 27  
under the appendix for a list of all  
error codes.  
Input power status indicator  
7
 
1.3.3. Using the control buttons  
You can turn on power manually for each of the eight output devices with  
the control buttons provided under each status indicator A through H.  
Each button allows you to set the remote control function as well as turn  
power on/off for each outlet manually.  
The control button has two modes of operation. Press the button  
repeatedly to switch between Remote Control mode and Power On/Off  
mode. When you press the control button, the IPS-0008 switches modes  
as follows:  
After switching modes, you need to press the control button again within  
5 seconds to change the mode status.  
Remote control mode  
1.  
Press the control button once. The remote control indicator starts  
flashing red.  
2.  
Now press control button again within 5 seconds and hold for more  
than 5 seconds. The remote control indicator starts flashing red at  
a faster speed and then inverts its original state.  
For instance, if remote control indicator is enabled (grey) before you  
press the control button, it turns on (red) after step 2, indicating that  
remote control is disabled.  
8
 
 
Power on/off mode  
1.  
Press the control button twice. The outlet power indicator starts  
flashing green.  
2.  
Now press control button again within 5 seconds and hold for more  
than 5 seconds. The outlet power indicator starts flashing green at  
a faster speed and then inverts its original state.  
For instance, if outlet power indicator is off (grey) before you press the  
control button, it turns on (green) after step 2, indicating that outlet power  
is turned on.  
1.4. Rear Panel  
220AC Model  
110AC Model  
9
 
 
Rear Panel Component  
Component  
Description  
1
2
Input power  
Connect to a power outlet.  
Breaker  
Prevents excessive current flow to protect  
the system.  
3
4
Power outlet (A ~ H)  
Dry contact port  
Connect a device to each power outlet to  
sup- ply power to it.  
Connect dry contact UPS that can be  
remotely managed through network card.  
This is currently not supported by the  
IPS-0008.  
5
Digital output  
Connect up to digital outputs that are  
normally open or normally closed.  
10  
 
2. Getting Started  
This section provides information about setting up the IPS-0008,  
connecting power, and connecting devices to it before you start using it  
for power management. Read this section carefully to learn how to  
connect various devices to it.  
2.1. Attaching the feet  
The IPS-0008 comes with four  
feet or spacers that are attached  
to the bottom. Use the four  
screws provided with the feet to  
attach the feet to the bottom of  
the IPS-0008 as shown:  
Note: You do not need to attach the feet if you are going to install the  
IPS-0008 in a rack.  
2.2. Attaching the ears  
The IPS-0008 is designed to be  
placed in a rack arrangement  
and comes with two ears that  
help you to move the device  
easily. Attach each ear with the  
three screws provided in your  
package as shown:  
11